Sign in →

Test Code 30549 Latex Allergen Panel

Performing Laboratory

Mayo Medical Laboratories

Methodology

Profile Information:
Unit CodeReporting TitleAvailable Separately
82746Banana, IgEYes
82761Kiwi Fruit, IgEYes
82787Latex, IgEYes
Refererence values apply to all ages.

Specimen Requirements

Specimen Type: Serum

Container/Tube: Red top or serum gel

Specimen Volume: 0.5 mL

Specimen Minimum volume: 0.05 mL x number of allergens plus 0.25 mL dead space for each 5 allergens requested

Additional Information: Designate specific allergens from list in Allergens - IgE Antibodies in Special Instructions.

Reference Values

Class  IgE kU/L   Interpretation

0

<0.35

Negative

1

0.35-0.69

Equivocal

2

0.70-3.49

Positive

3

3.50-17.4

Positive

4

17.5-49.9

Strongly positive

5

50.0-99.9

Strongly positive

6

≥100.0

Strongly positive

Reference values apply to all ages.

Reporting Title

Latex Allergen Panel

Specimen Transport Temperature

Refrigerate/Frozen OK/Ambient OK

Day(s) Test Set Up

Monday through Saturday

Test Classification and CPT Coding

86003 x 3